# Why Rainheads, Sumps and Overflows Deserve More Attention in Roof Drainage Design

> Source: https://www.ppcflashings.com.au/why-rainheads-sumps-and-overflows-deserve-more-attention-in-roof-drainage-design/  
> Author: Cameron Pryde  
> Date: 2026-10-26T08:24:39+11:00

In roofing terms, the failure of the roof drainage system can cause significant problems within a building. Although the apparent problem is located on the roof, such as leaking from the ceiling or ingress of water into the walls of a building, there can be greater and more expensive problems hidden elsewhere within the building. All such problems originate from defects in the design and/or installation of the roof drainage system. Building research in Victoria has recently been focused towards the area of roof drainage problems including defects with rainheads, sump overflows and other parts of the roof plumbing.

 The comments regarding Roof Drainage in building construction are extremely important for the Builder, Roofer, Designer and project manager to understand in order to ensure proper completion of the building’s details.

 

## Victorian Research Highlights Roof Drainage Defects

 Research conducted by [Victoria’s Building Commission (VBA)](https://www.vba.vic.gov.au/about/research/examining-moisture-related-disputes-in-victorian-residential-buildings) as part of Examining Moisture Related Disputes in Residential Buildings identified several recurring issues in regards to roofing and roof plumbing including rainheads and sump overflows. Many of the issues identified with gutters were related to installation. The issues raised with regards to roofing and roof plumbing (including use of rainheads and sump overflows) as well as problems with the installation of gutters were identified through various Victorian Building and Plumbing Commission (VBA) inspection reports. This research into residential homes is fascinating and highlights potential problems with the roof drainage of commercial and industrial properties too.

 An adequate roof drainage system must be capable of dealing with rainwater flows during normal rainfall events. In addition, the system must also be designed to prevent water accumulating in roof spaces and to safely overflow should water fail to drain from the roof for any reason (e.g. blockage of an outlet). The research identifies several key matters for roof drainage including roof configurations that incorporate box gutters, enclosed roof drainage systems and areas where uncontrolled overflow may result in internal damage.

 

## Understanding the Role of Rainheads

 A rainhead is typically attached to the top of a downpipe at where the gutter ends. Depending on its form, the rainhead acts as a transition from the gutter to the downpipe. It manages water from the roof and can also manage the overflow from the gutter. Again, not all rainheads provide the same level of performance with respect to overflow.

 Importantly, the dimensions of the rainhead, the outlet(s) and the relationship between the rainhead and the surrounding gutter must all be considered during the design of the roof drainage system. PPC Flashings custom fabricates a number of [Rainhead types](https://www.ppcflashings.com.au/rainheads/) including Standard, Curved, Tapered, Oval, Concave and Half Circle styles in order to accommodate various Architectural requirements, Gutter types and Building specifications. They allow roofing contractors to specify the appropriate Rainheads for architectural purposes while providing the necessary options to design around different Gutter setups and Building specifications. For commercial and architectural structures, PPC can manufacture rainheads in custom designs to create consistent appearances while fulfilling unusual dimensions and building structures.

 

## Why Sumps Matter in Box Gutter Systems

 Sumps serve a different function from rainheads. The Sump is typically located in the lowest section of a Box Gutter to collect water and then discharge this water through the outlet or downpipe. Note: dimensions, location & outlet capacity must all be designed and installed to match up to form part of the overall hydraulic design of the system. In particular, an incorrectly sized sump, a blocked outlet or incorrect connection of the sump to the rainwater outlet can cause water to collect in the roof space of a building and in some cases leak into internal walls and ceilings of a building.

 For concealed box gutters of buildings such as homes and offices, the consequences of an overflow entering into internal spaces could be disastrous. PPC Flashings supplies a wide range of [rainwater goods](https://www.ppcflashings.com.au/rainwater-goods/) including sumps and downpipes. They can also provide custom fabrication of sumps to your specific requirements. The option for custom fabrication is very important as standard components are usually limited to standard sizes and configurations to ensure that they can be designed by others and fit into most applications.

 

## Overflow Protection Is Not Optional

 Roof drainage design needs to include provision for overflow flow, to occur when the capacity of the drainage system is exceeded. An overflow arrangement will function to allow water to flow via an alternative path to that of the normal roof water drainage flow when the primary drainage system cannot deal with the flow that is entering the roof water drainage system. Under the Plumbing Code of Australia for Victoria’s roof drainage requirements refer to drainage capacity and overflow. Please note that the recent Victorian research into building moisture problems highlights that many problems with building moisture are caused by details that are generally given little consideration in design and construction.

 In Roof Drainage details this includes rainheads, sumps and overflows. It is not safe to assume that a rainhead or sump forms the emergency overflow for a roof drainage system. That must form part of the total design and be installed correctly in accordance with relevant installation requirements.

 

## Fabrication Accuracy Supports Better Installation

 Correct drainage design is only part of the equation. The roof plumbing components need to be fabricated to the exact size of the design and installed in accordance with the design. The plumbing contractor benefits from having accurate made plumbing components to achieve the correct connections, particularly at the junctions of gutters and downpipes, as well as the correct positioning of outlets. This is especially important when you are working with unusual shapes of roofs, special architectural features or complex commercial gutter arrangements.

 It is very important that when ordering custom plumbing products for projects that the contractor providing the details for the fabrication of these products includes all dimensions and material requirements as well as approved fabrication details to minimize changes to the product during installation.

 

## Bringing Roof Drainage Details Together

 Recent Victorian research into building moisture problems has identified many of the problems are due to minor details that are frequently overlooked by designers and builders. Many buildings are designed so that water cannot drain safely from the roof without being managed by a roof drainage system, which involves rainheads, sumps and overflows. PPC Flashings produces a wide variety of custom made rainwater goods and other related metal components to assist roofing contractors, builders and designers. Building envelope components are important to manage in building design, but one of the most important is managing water to stop it entering the building.

 A good roof drainage design, with accurately fabricated roof plumbing components and installed by professionals, is all needed to achieve this.